Specific target organ toxicity – repeated exposure Category 1
(liver, kidney, cardiovascular system);
Skin corrosion/irritation Category 1A
;
Reproductive toxicity Category 2
;
Carcinogenicity Category 2
;
Flammable liquids Category 2
;
Acute toxicity Category 3
(dermal);
Acute toxicity Category 3
(inhalation - dusts and mists);
Specific target organ toxicity – single exposure Category 3
(respiratory system);
Specific target organ toxicity – single exposure Category 3
(central nervous system);
Acute toxicity Category 4
(oral);
Acute toxicity Category 4
(inhalation - vapours)
Storage
Not stored at nanoFAB (kept in user's lab and brought to cleanroom for processing).
Disposal
Seal all waste (including foil liners, pipettes, cleanroom wipes, etc.) in a large Ziploc bag, and dispose of in red organic sharps waste pail in secondary litho area. Ziploc bags are provided in the cabinet at the end of the wet aisle table, opposite the resist fridges. All waste, including developer rinses, would need to be collected in a segregated waste bottle for disposal as hazardous waste.
Comments
All spin-coating and soft-baking must occur in Aisle 1 fumehood, with the sash kept as closed as possible. Must be spun on in foil-lined Headway spinner and fully soft-baked on a foil-lined hot plate in the fumehood. May be exposed in the Nanoscribe PPGT+ (oil immersion mode or 20× air objective only: no immersion (DiLL) mode allowed) or Heidelberg MLA150.
Status
RESTRICTED USE
Check First
Please contact a nanoFAB staff member for uses not listed above.